Skip to main content

Table 2 Cmax ± SEM (ng/mL) for human plasma samples from 8 subjects that were assayed with and without enzymatic hydrolysis

From: The fallacy of enzymatic hydrolysis for the determination of bioactive curcumin in plasma samples as an indication of bioavailability: a comparative study

NON-HYDROLYZED

HYDROLYZED

Curcumin

Curcumin Glucuronide

Total Curcumina

Curcumin

Tetrahydrocurcumin

Total Curcumina

0.71 ± 0.71

28.8 ± 13.4

19.5 ± 9.0

129.4 ± 44.7

313.5 ± 45.0

369.1 ± 39.1

  1. aCorrected—curcumin quantity from each form adjusted by molecular weights for each analyte